直流電機維修換向器修理后檢查方法:
1、用(yong)小鐵錘輕敲換向(xiang)片,依據發(fa)出的聲(sheng)音來判斷(duan)安裝是否牢固。若發(fa)出較清(qing)脆的聲(sheng)音,表(biao)明換向(xiang)器裝配牢固;如果發(fa)出空(kong)殼聲(sheng),則表(biao)明換向(xiang)器松弛,要重新(xin)裝配。
2、檢查換(huan)向片(pian)的軸向平(ping)行度(du),使換(huan)向片(pian)沿軸線的偏斜(xie)度(du)不超過片(pian)間云母片(pian)的厚(hou)度(du),否(fou)則會(hui)造成換(huan)向不良(liang)。
3、做對(dui)地耐壓(ya)(ya)試(shi)驗,試(shi)驗電壓(ya)(ya)通常為(wei)兩倍的額定電壓(ya)(ya)加1000V,持續時間為(wei)1min。
4、用220V檢驗燈逐片(pian)檢查(cha)片(pian)間是否(fou)短路,若有短路應加以排除。
山東子昂機(ji)(ji)(ji)(ji)(ji)電(dian)(dian)(dian)(dian)設備有限(xian)公司(si)是一家專注高低壓電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、電(dian)(dian)(dian)(dian)氣產品的(de)維修(xiu)(xiu)(xiu)、研發(fa)、生產、銷售和服務(wu)為一體的(de)科(ke)技型企業。本公司(si)專業維修(xiu)(xiu)(xiu):西(xi)安西(xi)瑪(ma)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、上海電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、中(zhong)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、蘭(lan)州電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、湘潭(tan)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、佳(jia)木斯電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、沈陽(yang)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、江西(xi)東元電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、無錫電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、六(liu)安電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、ABB電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、西(xi)門子電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)等各大型高低壓電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、直(zhi)流電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、發(fa)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)、防爆電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)及同(tong)步電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)(ji)(ji)維修(xiu)(xiu)(xiu)、維護(hu)、保養及現場拆檢等服務(wu)。